KOBOtect Sun Block Film Product List

Part No.: TSM-87C

UV
0.0%
IR
0.6%
VLT
87.4%

Part No.: TSM-80C

UV
0.0%
IR
3.5%
VLT
81.1%
item's stock number visible ray
Transmittance(%)
(Highest price)
infra-red rays
Transmittance(%)
(Highest price)
ultra-violet rays
Transmittance(%)
300nm~380nm
solar radiation shielding factor thermal transmittance
(w/m²k)
solar heat
acquisition rate
solar heat
rejection rate
Transmittance(%) Reflectance (%) Absorption rate (%)
TSM-87C 87.4 0.6 0.0 58.3 7.4 34.3 0.79 5.9 0.70 0.30
TSM-80C 81.1 3.5 0.0 38.8 6.0 55.2 0.66 6.0 0.58 0.42

*All data above are measured by a third-party organization.

*Measurement method is based on JIS A 5759:2016.

Visible light transmittance is the highest value measured by a third-party organization in the wavelength range of 400 nm to 780 nm.

*Infrared transmittance is the highest value measured by a third-party organization in the 780nm to 2500nm wavelength range.

*UV transmittance is the value measured by a third-party organization in the wavelength range of 300 nm to 380 nm.

*Measurements are made with a film applied to transparent float glass (3 mm thick).

The above values are measured values, not guaranteed values.

Specifications are subject to change without notice.

*The spec values on the website are the latest values.
*Differences from the values in catalogs may occur when products are improved.

Part No.: TSM-J30S

UV
0.0%
IR
1.2%
VLT
32.9%

Part No.: TSM-J10S

UV
0.0%
IR
2.9%
VLT
15.1%

Part No.: TSM-J05S

UV
0.0%
IR
2.0%
VLT
11.0%
item's stock number visible ray
Transmittance(%)
(Highest price)
infra-red rays
Transmittance(%)
(Highest price)
ultra-violet rays
Transmittance(%)
300nm~380nm
solar radiation shielding factor thermal transmittance
(w/m²k)
solar heat
acquisition rate
solar heat
rejection rate
Transmittance(%) Reflectance (%) Absorption rate (%)
TSM-J30S 32.9 1.2 0.0 16.4 5.1 78.4 0.49 6.0 0.43 0.57
TSM-J10S 15.1 2.9 0.0 8.1 4.9 87.0 0.43 6.0 0.38 0.62
TSM-J05S 11.0 2.0 0.0 5.5 4.4 90.1 0.41 6.0 0.36 0.64

*All data above are measured by a third-party organization.

*Measurement method is based on JIS A 5759:2024.

Visible light transmittance is the highest value measured by a third-party organization in the wavelength range of 400 nm to 780 nm.

*Infrared transmittance is the highest value measured by a third-party organization in the 780nm to 2500nm wavelength range.

*UV transmittance is the value measured by a third-party organization in the wavelength range of 300 nm to 380 nm.

*Measurements are made with a film applied to transparent float glass (3 mm thick).

The above values are measured values, not guaranteed values.

Specifications are subject to change without notice.

*The spec values on the website are the latest values.
*Differences from the values in catalogs may occur when products are improved.

PAGE TOP